                              B-mode real time ultrasonographic imaging of the 
                              heart in sheep - 
                              A Aissi
                              Vet World. 2011; 4(10): 467-469
               
              
              
              doi: 10.5455/veworld.2011.467-469
              
              
               
              
              
              
   
 
              
               
               
               
              
              
              Abstract
              
                              
                              
                              
                              The anatomical structure of normal heart was 
                              studied in vitro through ultrasonography of 27 
                              healthy hearts of sheep collected following 
                              slaughter. Ultrasonography was done in the water 
                              with 25o C by sectorial transducer from 2 cm 
                              distance. In the laboratory, the waves of 
                              ultrasonography were sent from right ventricle 
                              (RV). The thickness of left ventricle wall (LV) 
                              (20.69±2.628mm), right ventricle wall (RV) 
                              (8.10±2.138mm) and inter ventricular space (IVS) 
                              (18.925±1.984mm) were measured by ultrasonography. 
                              After preparing ultrasonogrphes obtained by in 
                              vitro ultrasonography were compared with natural 
                              anatomical views. Also biometrical measurements 
                              were compared with sizes were measured by 
                              ultrasonography measurement. Biometrical 
                              measurements were performed by a special ruler 
                              (caliper) right ventricle thickness (7.6±1.957mm), 
                              left ventricle thickness (19.20±1.563mm) and 
                              inter-ventricular space thickness is 
                              (17.981±1.786mm). Keywords: 
                              Ultrasonography, heart, sheep, anatomy.